Validynamics

Standard Hysteresis Brakes

From our humble beginnings with a small hysteresis brake, we have grown to make it the core of our flagship products.

Standard Hysteresis Brake

Standard Hysteresis Brakes

Single output brakes (-B, -C) and double ended output brakes (-A) are available. The selection of them depending on the space of installation. It is widely used in high speed winding equipment, electrical equipment, small scale internal combustion engines, loading-life simulation system of gear boxes and other rotary devices, accurate load for high-ended sports equipment, etc. It can be used as loading for motor tests.

Specifications:

ModelMinimum torque at Rated CurrentRated CurrentVoltageResistance at 25℃±10%WeightKinetic PowerExternal InertiaMax Rated Speed
5 minutesContinuous
 kg·cmN·mmAVDCOhmkgwattswattskg·cm2rpm
HB-3000.030.003135241800.12823.3 x 10-420000
HB-2010.20.02192241250.152561.5x 10-320000
HB-3010.30.03208241150.173086.8 x 10-320000
HB-5010.50.05208241150.213086.8 x 10-320000
HB-10210.1200241200.3955154.6 x 10-220000
HB-20220.2203241180.5175206.8 x 10-215000
HB-30230.339324611.35120351.8 x 10-115000
HB-50250.539324611.35120351.8 x 10-115000
HB-10310125024961.8350801.1 x 10015000
HB-20320231524763.54601153.2 x 10010000
HB-30330375024325.26801656.8x 10010000
HB-50350575024329.610002001.3 x 10110000
HB-603606150024189.614002251.4 x 10110000
HB-124120121200242018.512003506.2x 1016000

Please contact for independent diagram of each model.

Remarks

  1. Single or double shaft of output can be chosen for all models.
  2. Most models can be customized to non-standard voltage rating
  3. Kinetic power ratings are maximum values based on limiting coil and bearing temperature to approximately 90 ºC. Actual values in practice may vary ±20% depending on mounting, ventilation, ambient temperature, etc